Specifications
Initial Setting Code
Not supplied
ANSI/RKC standard
MODBUS
No CT1 and CT2
CT1 : CTL-6-P-N, CT2 : No use
CT1 : CTL-12-S56-10L-N, CT2 : No use
CT1 : CTL-6-P-N, CT2 : CTL-6-P-N
CT1 : CTL-12-S56-10L-N, CT2 : CTL-12-S56-10L-N
Output logic selection
Event 1 type
Event 2 type
Event 3 type
Event 4 type
CT type
0 to 10mV DC
0 to 100mV DC
0 to 1V DC
0 to 5V DC
0 to 10V DC
1 to 5V DC
0 to 20mA DC
4 to 20mA DC
See output logic code table.
Not supplied
See event type code table
Not supplied
See event type code table
Not supplied
See event type code table
Not supplied
See event type code table
LBA (Control loop break alarm)
Communication 1 protocol
Remote setpoint
input signal
1
2
3
4
5
6
7
8
N
N
N
N
N
P
S
T
U
N
1
2
Output Logic Code Table.
Accessory
Event Type Code Table.
5
• Quick start code 2 tells the factory to ship with each parameter preset to the values detailed as specified by the customer.
Quick start code is not necessarily specified when ordering, unless the preset is requested.
These parameters are software selectable items and can be re-programmed in the field via the manual.
1
Code
2
3
4
5
6
7
Output 1
(OUT 1)
Output 2
(OUT 2)
Digital Output 1
(DO 1)
Digital Output 2
(DO 2)
Digital Output 3
(DO 3)
Digital Output 4
(DO 4)
Control
output 1
Control
output 1
HBA
HBA
HBA
HBA
HBA
FAIL
Control
output 1
Control
output 1
Control
output 2
Control
output 2
Control
output 2
Control
output 2
Control
output 1
Control
output 1
Control
output 1
(De-energized)
Event 1
Event 1
Event 1
Event 1
Event 1
Event 1
Event 1
Event 2
Event 2
Event 2
Event 2
Event 2
Event 2
Event 3
Event 3
Event 3
Event 3
Event 3
Event 3
Event 4
Event 4
Event 4
Event 4
FAIL
(De-energized)
FAIL
(De-energized)
• Energized/De-energized is configurable except for the FAIL output.
(Factory default setting: Energized)
• Invalid for a non-existing output/event function.
(Caution)
When used as heating/cooling control/position proportioning
control, select any code of 1 to 4.
* Please specify "8" when the remote setpoint input signal is not used.
Code
Event type
Deviation High
Deviation Low
Deviation High/Low
Band
Deviation High with Alarm Hold
Deviation Low with Alarm Hold
Process High with Alarm Hold
Process Low with Alarm Hold
A
B
C
D
E
F
Deviation High/Low with Alarm Hold
Deviation High with Alarm Re-Hold
Deviation Low with Alarm Re-Hold
Deviation High/Low with Alarm Re-Hold
Process High
Process Low
G
H
J
K
L
Q
R
T
Set value High
Set value Low
MV value High
MV value Low
Cool side MV value High
Cool side MV value Low
V
W
1
2
3
4
Model Code :
Terminal cover
KFB400-58
(FB900 uses 2 unit)
FB400
FB900
Max.63
Max.70
Max.68
2-M4
59
59
±0.5
50
Mounting dimension
* Supplied when power feed forward function is specified.
* When ordering transformer for replacement,
please specify one of the following model codes.
100 to 120V AC type : PFT-01
200 to 240V AC type : PFT-02
(For Power feed forward input)
±1
±0.2
Model code
Current transformer for
heater break alarm (HBA)
CTL-6-P-N (0 to 30A)
CTL-12-S56-10L-N (0 to 100A)
(Sold separately)
(Sold separately)
CTL
-
6
-
P
-
N
CTL
-
12
-
S56
-
10L
-
N
(Unit : mm)
φ 5.8
14.5
25
21
10
Approx.130
φ 12
M3 Depth 4
40
30
40
7.5
15
Approx.100
(Unit : mm)
Temperature/Process Controller FB900/400
Quick Start Code 2
9FB_01E